Description SILBIONE MM SERIES 71791 U are silicone rubbers which cure
after addition of a vulcanising agent (chosen as a function of the
production process).
This series includes four products which differ by their hardness
once cured : 40-50-60 and 70 Shore A.
Once processed SILBIONE MM SERIES 71791 U , "Food contact
and biomedical grade" are intended for:
· biomedical applications
· applications requiring a material that is non-toxic under normal
conditions of use and inert to food products.
SILBIONE MM SERIES 71791 U , are elastomers comprising
polymethylvinylsiloxane gums and silica. They heat cure after
addition of an organic peroxide compound. This vulcanisation must
be followed by post curing at 200°C.
Special properties · Easy processing
· Highly transparent
· Excellent mechanical properties, including high tear strength
and a good compromise between tear strength and
compression set
· Very good resistance to oxidising agents (oxygen, ozone, UV)
· Very good behaviour for all sterilisation modes
· Very good release properties
· Chemically inert
Regulations The composition of SILBIONE MM SERIES 71791 U enables them to
be used in conformity with the definitions in the following European and
American regulations.
Food contact:
France : Journal Officiel – Brochure 1227– order dated 25 November
1992.
Germany : BGVV XVA and LIIA.
United States : : US- FDA- CFR 21- part 177. 2600.
Italy : Gazetta Ufficiale – law dated 1973 and addendum.
Moreover, samples of SILBIONE MM SERIES 71791 U, catalysed
with dichloro- 2, 4 benzoyle peroxide, have been subject to
migration tests in accordance with European regulations: Directives
82/ 711/ EEC and 93/ 8 EEC and American regulations: US- FDACFR
21- part 177. 2600.
Regulations Drinking water contact
SILBIONE MM SERIES 71791 U of hardnesses 50 and 60 ShA, have
been successfully proven to be in conformity with German KTZ
regulation part 1.3.13.
Medical devices.
Basic biological studies; cytotoxicity, irritation, sensitisation and
hemocompatibility, required by directive 93/42 CE dated June 14
1993, relative to medical devices and USP Class VI of US, have
been carried out on samples of SILBIONE MM SERIES 71791 U ,
catalysed using dichloro 2,4 benzoyle peroxide.
The summaries of the biological studies are available on request.
In all cases it is the finished article manufacturer’s
responsibility to check conformity with the tests imposed by
the appropriate regulations.
For medical applications, Rhodia Silicones SAS forbids the
commercialisation of these elastomers for the production of
medical devices:
· implanted for more than 29 days
· in contact for more than 29 days with blood and the
mucous membranes (contraception, obstetrics)
· for plastic surgery
Applications SILBIONE MM SERIES 71791 U , once catalysed and processed is
recommended for the manufacture of the following articles:
Those which enter in contact with food such as :
· Tubes for drink distribution, including potable water
· Baby’s bottle tops
· Various technical parts.
· Sections, sleeves, calendered sheets, belts and conveyor belts
Those used in pharmacy such as:
· Tubes and piping for the circulation of liquid or soluble
medicines
· Medicine conveyor belts, etc.
Those used for medical applications such as:
· Tubes and piping for extra-corporal circulation
· Oxygenotherapy tubes
· Self-injectable syringe seals
· Breathing masks
Quality Assurance 1- Manufacture
Rhodia Silicones takes particular care in manufacturing and quality
control in order to guarantee users with the supply of an elastomer
whose quality level is in conformity with the special requirements in
these types of application:
· lack of cross-pollution.
· high level filtration.
· Specific controls.
All of these operations are part of Rhodia Silicones’ quality control
policy, certified to ISO 9001.
Quality Assurance 2- Control
Specific controls are carried out on each batch of SILBIONE MM
SERIES 71791 U to meet the various regulations.
The results are written on the analytical test certificate in addition to
the mechanical characteristics.
SPECIFICATION FOOD GRADE MEDICAL GRADE
ON POST CURED VULCANISED PRODUCT
Identity : IR Spectrum In Conformity m m
Volatile content (%):
(200°C-10g-4h)
0.5 maxi. m
Residual peroxides (%) 0.08 maxi. m
Mineral oils (fluorescence) In Conformity m
ON AQUEOUS EXTRACT
Turbidity (NTU) 4 maxi. m
Alkalinity (ml 0.01 M HCl) 1 maxi. m
Acidity (ml 0.01M NaOH) 1.5 maxi. m
Reducing substances
(ml 0.01 M Na2 SO3)
1 maxi m
ON HEXANE EXTRACT
Hexane soluble (%) 3 maxi m m
Phenyl compounds (DO/UV) 0.4 maxi. m
Heavy metals (ppm) (other than
aqueous extract)
10 maxi m
Processing methods The choice of vulcanising agent (peroxide) to add to the SILBIONE
MM SERIES 71791 U depends on the processing method and the
conformity with various “Food contact grade” regulations.
The various processing methods are summarised in the table
below:
SILBIONE
MM SERIES 71791 U
Dichloro- 2, 4 benzoyle
Peroxide at 50 %
(E)
Dicumyl Peroxide
at 95 %
(D)
2, 5 dimethyl-
2, 5- di (tertio- butylperoxy)
hexane at 72 %
(L)
compression
Moulding injection
0.6 parts per 100
master batch
0.6 parts per 100
master batch
hot air vulcanisation 0.9 to 1.25 parts per 100
master batch
6 to
12 bar
0.6 parts per 100
Extrusion pressurised master batch
steam
vulcanisation
12 to
20 bar
0.6 parts per 100
master batch
Calandering hot air vulcanisation
0.9 to 1.25 parts per 100
master batch
Characteristics 1- Physical properties
Type (according to AFNOR T 40002)....... .................................MVQ
Hardness Specific gravity at 25 ° C, approx.
40 ShA 1.10
50 ShA 1.13
60 ShA 1.15
70 ShA 1.18
Characteristics Natural colour......................... ........................................Transparent
2- Mechanical properties
Below we give an example of the characteristics obtained using
dichloro- 2, 4 benzoyle peroxide (at 50%) as a vulcanising agent.
Measurements are made on a 2 mm thick moulded sheet, cured for
8 min at 115°C and post cured for 4 hours at 200°C.
SILBIONE MM SERIES 71791 U 71 791/40 U 71 791/50 U 71 791/60 U 71 791/70 U
Peroxide dose in parts per 100 of master batch 0.9 1 1.25 1.25
ShA hardness , points, approx
(Standard ASTM D 2240)
43 53 62 72
Tensile strength, MPa, approx,
(Standard AFNOR NF T 46- 002)
9.0 9.5 10 9.5
Elongation at break, %, approx,
(Standard AFNOR NF T 46- 002)
600 640 500 410
Tear strength, kN/m, approx,
(Standard ASTM D 624 A)
31 38 38 34
Compression set ( 22h/ 177°C/ 25%), %, approx,
(Standard ASTM D 395 B)
27 34 40 40
Rebound resilience (thickness 8 mm), %, approx,
(Standard DIN 53 512)
50 45 42 37
Linear shrinkage %, approx, 3.5 3.7 3.7 4.0
SILBIONE MM SERIES 71791 U must be post cured at 200°C
after vulcanisation (it is recommended not to exceed this
temperature).
Post curing is essential in order to :
· Ensure conformity with the legislation and regulations currently
in force
· Stabilise the mechanical properties of the elastomer as well as
its dimensions
· Ensure the heat stability of the elastomer
· Improve its chemical resistance, especially with respect to
solvents, fats and steam
Processing 1- Adding peroxide to SILBIONE MM SERIES 71791 U
This operation is performed on a two-roll mixing mill.
Operating procedure :
à Check that the equipment is scrupulously clean in order to avoid
including impurities that would detract from the quality and properties of
the SILBIONE MASTER BATCH.
à Plasticise the SILBIONE MASTER BATCH.
Use of a back / front roller speed ratio of between 1.25 and 1.4 ensures
sufficient friction to give good plasticising.
à Add the peroxide, then mix by cutting and crossing.
à Cool the cylinders throughout the operation in order to maintain the
SILBIONE MASTER BATCH at a temperature below 30°C;
In the case of catalysis using crystalised dicumyl peroxide, after
dispersion it is recommended to heat the elastomer to 50°C to ensure the
fusion of the peroxide, then to cool to 30° once fully incorporated.
2- Processing
SILBIONE MM SERIES 71791 U obtained in this way can be
processed using all conventional methods in the rubber processing
industry used for traditional materials.
Processing In this way, using SILBIONE MASTER BATCH plasticised on a
two-roll mixing mill, we could:
à Either roll a sheet to the required thickness from which we will cut
preforms for moulding.
à or cut bands that will be used for example to feed an injection press or
to prepare sheets for calendering.
3- Vulcanisation and post curing
Vulcanisation of SILBIONE MM SERIES 71791 U is carried out at
temperatures according to the type of peroxide used.
Once cured we remind you that SILBIONE MM SERIES 71791 U
must be post cured at 200°C in forced air ovens with protected
heating elements.
The post cure duration depends on the thickness of the parts
obtained (moulded, extruded or calendered).
Post curing gives the elastomer its optimum characteristics and ensures
its conformity with the requirements of the regulations currently in force.
Important comments :
Post curing at a temperature above 200°C or any accidental increase in
temperature (e.g. to around 250-300°C) can damage parts causing
stiffening, cracking or formation of a surface glaze. It is therefore
important to use good temperature control together with forced air
ventilation.
Non-ventilated ovens or those with insufficient ventilation can cause
"reversion" to occur : a reduction in hardness due to the onset of
depolymerisation.
Important notice RHODIA SILICONES SAS guarantees the properties given for
SILBIONE MM SERIES 71791 U .
However, our company cannot guarantee the behaviour of this master
batch and the application that is made of it by the user, since it has no
control over the conditions of application nor the process under which a
study has been conducted.
Packaging SILBIONE MM SERIES 71791 U are available in 25 kg reinforced
cardboard cartons. Each master batch is enclosed in a release
coated sheet.
Storage and
shelf life
SILBIONE MM SERIES 71791 U may be stored in its original
unopened packaging at a temperature below +40°C for up to 18
months from the date of manufacture marked clearly on the
packaging.
Past this date, Rhodia Silicones no longer guarantees that the
product meets the sales specifications.When kept in its original
unopened packaging,
According to the hardness, it is recommended to slightly refreshen
SILBIONE MM SERIES 71791 U before using.
Comment : Prolonged storage beyond the recommended expiry date
generally means a reduction in hardness and an increase in refreshening
time
Safety Please refer to the Safety Data Sheets for SILBIONE MM SERIES
71791 U .
Warning to users The information contained in this document is given in good faith
based on our current knowledge. It is only an indication and is in no
way binding, particularly as regards infringement of or prejudice to
third party rights through the use of our products.
RHODIA SILICONES GUARANTEES THAT ITS PRODUCTS
COMPLY WITH ITS SALES SPECIFICATIONS.
This information must on no account be used as a substitute for
necessary prior tests which alone can ensure that a product is
suitable for a given use.
Users are responsible for ensuring compliance with local legislation
and for obtaining the necessary certifications and authorisations.
Users are requested to check that they are in possession of the
latest version of this document and RHODIA SILICONES is at their
disposal to supply any additional information.